Cremer 1230 Tablet Counter

Cremer 1230 Tablet Counter

orCall 323.588.4141

Description

Used Cremer 1230 12-lane Tablet Counter, Model CF1230-S006, Serial 873200DA, 220/60/3, built 1993. The Cremer CF-1230 is a 12-channel linear tablet and capsule counter, counts any kind of tablet, hard or softgel capsule. Includes bulk hopper with gate, linear vibratory plates for optimal product separation, 12-channel detection unit, and (2) filling nozzles with dust collection port with Operational Manual included

Specifications:

  • Counter: Count Value
  • Precount: Count value -30 (Max:100)
  • Start Seperation Speed: Count value -30
  • Counting speed: See how produvt reacts on plate(front)
  • Separations Speed: Counting speed -10
  • Hopper: 90
  • Hopper Frequency: Adjust it so it will not overfill the front plate
  • Hopping time: Value between 4 and 6
  • Rejection/min: 2
  • Nozzle vibration: 0, No vibration 4: vibration
  • Counting Mode: 0 counts higher than 10, 1: count lower than 10
  • Count Sensor delay: Set at 0, unless machine is doing undercounts(rotating Products)
  • Product width: Smallest product width- 1 mm
  • Container size: Size of container for indexing purpose

Specifications

ManufacturerCremer
ModelCF-1230
ConditionUsed
Serial NumberCremer 234, CLI 873200DA
Inventory #12288
* PrecountCount value -30 (Max
* Start Seperation SpeedCount value -30
* Rejection/min2